FAC0420-02

3-Channel 4–20 mA Current Sensor

The 3-Channel 4–20 mA Current Sensor from Fidar Electronics reads the standard 4–20 mA output of any industrial transmitter and maps it back to engineering units. It connects to a FIDAQUIRE data logger over a daisy-chained CANopen bus.

  • Standard 4–20 mA input
  • Three independent input channels in one unit
  • Works with any industrial 4–20 mA transmitter
  • Broken-wire detection below 4 mA
  • RJ45 output on a CANopen bus
  • Daisy-chains up to 64 sensors per card
  • Works with the FBC0232-01 card and FIDAQUIRE logger
  • Up to 500 m of bus at 125 kbit/s

The 3-channel 4–20 mA sensor is an industrial analog input module designed to receive and monitor signals from three independent industrial transmitters simultaneously. It allows three measurement devices with standard 4–20 mA current outputs to be connected to the FIDAQUIRE monitoring system.

The module supports various industrial transmitters, including pressure, level, flow, temperature, humidity, and pH transmitters. The conversion of current signals into physical measurement units, such as bar, meters, or degrees Celsius, is configured in the monitoring software.

One of the key advantages of the 4–20 mA standard is its live-zero principle, where 4 mA represents the zero measurement value. Therefore, a current below the specified 4 mA threshold can indicate a broken wire or transmitter fault. This allows the system to identify signal faults separately instead of incorrectly recording them as zero measurements.

Key features of the 3-Channel 4–20 mA Sensor

  • Three independent input channels for industrial transmitters

  • Independent broken-wire and signal fault detection on each of the three input channels when the current drops below 4 mA.

  • Standard 4–20 mA current signal input

  • Compatible with industrial transmitters featuring 4–20 mA outputs

  • Broken-wire and input signal fault detection below 4 mA

  • RJ45 interface for CANopen bus communication

  • Daisy-chain connection of up to 64 sensors per card

  • Compatible with the FBC0232-01 card and FIDAQUIRE data logger

  • Communication distance of up to 500 meters at a transmission rate of 125 kbps

Communication and Connectivity

The 3-channel 4–20 mA sensor connects to the CANopen communication bus through its RJ45 interface and transmits measurement data to the FIDAQUIRE monitoring system at a communication rate of 125 kbps.

With three independent input channels, the module can acquire signals from three separate industrial transmitters. Furthermore, the ability to connect up to 64 sensors in a daisy-chain configuration on the FBC0232-01 card allows the monitoring system to be expanded to cover multiple measurement points.

The module also supports input signal fault detection and fault reporting through the data logger.

Each of the three input channels independently detects signal faults, and the fault status of each channel is reported separately through the data logger.

Where it is used

  • Reading pressure, level, flow and temperature transmitters

  • Tank and pipeline monitoring in oil, gas and petrochemicals

  • Bringing environmental analysers into a monitoring system

  • Pumping stations and water/wastewater treatment plants

  • Retrofitting legacy instruments into a modern monitoring stack

  • Air-quality and emission-measurement systems

Installation

To ensure reliable communication and minimize electromagnetic interference, shielded twisted-pair cables are recommended for the communication path.

The cable shield should be grounded at only one end to prevent ground loops. Proper cable routing and equipment connections also help improve communication stability and ensure reliable system operation.