FDV0220-01
AC Voltage Detector
The AC Voltage Detector from Fidar Electronics reports whether an AC line up to 220 V is live and timestamps every loss and restore. It connects to a FIDAQUIRE data logger over a daisy-chained CANopen bus.
Detects AC voltage presence up to 220 V
Immediate power-failure alert with a timestamp
A definite two-state answer, no value to interpret
RJ45 output on a CANopen bus
Daisy-chains up to 64 sensors per card
Works with the FBC0232-01 card and FIDAQUIRE logger
Up to 500 m of bus at 125 kbit/s
Power and data share one cable
An AC voltage detector reports whether a line is live. Unlike a level sensor that returns a number, it gives a definite two-state answer, which is exactly what the job needs: mains-failure alerts, proving a transfer to generator or UPS, and confirming that critical circuits are energised. Every transition is timestamped, so the outage duration stays in the record instead of relying on someone's memory.
Key features
Detects AC voltage presence up to 220 V
Immediate power-failure alert with a timestamp
A definite two-state answer, no value to interpret
RJ45 output on a CANopen bus
Daisy-chains up to 64 sensors per card
Works with the FBC0232-01 card and FIDAQUIRE logger
Up to 500 m of bus at 125 kbit/s
Power and data share one cable
Connectivity
RJ45 CANopen output running at 125 kbit/s
Daisy-chain of up to 64 sensors on one FBC0232-01 card
Automatic input-break detection reported to the logger
Where it is used
Mains-failure alerts at remote sites and stations
Proving load transfer to a generator or UPS
Confirming critical circuits and emergency lighting are live
Feeder status on a distribution board
Telecom sites, BTS towers and equipment rooms
Logging outage count and duration for maintenance reports
Installation
Wire the input in parallel with the monitored line; installation must be carried out by a qualified electrician under low-voltage safety rules.
| Dimensions | Height 3 cm, Depth 12 cm, Width 10.5 cm |
|---|---|
| Weight | 0.3 kg |
| Operating temperature | -10 to 45 °C |
| Storage temperature | -20 to 60 °C |
| Operating humidity | 0 to 60%, non-condensing |
| Warranty | 2 years |
| Mount | 2 Wall-mount holes |
| Input | 0 to 220v AC |
| Output | RJ45 CANopen bus |
An AC voltage detector reports whether a line is live. Unlike a level sensor that returns a number, it gives a definite two-state answer, which is exactly what the job needs: mains-failure alerts, proving a transfer to generator or UPS, and confirming that critical circuits are energised. Every transition is timestamped, so the outage duration stays in the record instead of relying on someone's memory. This model reports over a CANopen bus. Sensors daisy-chain onto a single shielded twisted pair that lands on an FBC0232-01 CANopen card inside a FIDAQUIRE data logger, so adding a station costs a tap on the existing cable instead of a new home run. Typical applications: • Mains-failure alerts at remote sites and stations • Proving load transfer to a generator or UPS • Confirming critical circuits and emergency lighting are live • Feeder status on a distribution board • Telecom sites, BTS towers and equipment rooms • Logging outage count and duration for maintenance reports
FDV0220-01-Usermanual-EN
v1.0 · EN · 811 KB