FTH1260-11
Wireless Type-K Thermocouple Sensor
The Wireless Type-K Thermocouple Sensor from Fidar Electronics measures high temperature with a Type-K thermocouple and automatic cold-junction compensation. It links over a LoRa radio with no cabling at all.
Type-K thermocouple input for high temperatures
Automatic cold-junction compensation
Fast thermal response for steep processes
LoRa radio link up to 1 km line of sight
AES-128 encrypted payloads
Pairs with the FWL1600-01 LoRa card
No cabling; pairing takes seconds
Low-battery warning per node
A Type-K thermocouple is a junction of two dissimilar metals that turns a temperature difference straight into a voltage. Its appeal is a very wide range, a fast response and tolerance of brutal conditions — which is why furnaces, burners and boilers use one where a PT100 would not survive. This sensor reads the thermocouple voltage and applies cold-junction compensation to recover the real process temperature.
Key features
Type-K thermocouple input for high temperatures
Automatic cold-junction compensation
Fast thermal response for steep processes
LoRa radio link up to 1 km line of sight
AES-128 encrypted payloads
Pairs with the FWL1600-01 LoRa card
No cabling; pairing takes seconds
Low-battery warning per node
Connectivity
LoRa link up to 1 km with AES-128 encryption
Quick pairing with the FWL1600-01 receiver card
Sensor-fault and low-battery warnings before the cell dies
Where it is used
Industrial furnaces and heat-treatment lines
Burners, steam boilers and combustion systems
Flue-gas and exhaust temperature measurement
Steel, foundry and glass industries
Extruder and mould temperature in plastics processing
Any point that needs a fast thermal response
Installation
Observe probe and compensating-cable polarity, and keep the tip out of direct flame radiation so the reading follows the process, not the fire.
| Dimensions | Height 3 cm, Depth 12 cm, Width 10.5 cm |
|---|---|
| Weight | 0.3 kg |
| Operating temperature | -10 to 45 °C |
| Storage temperature | -20 to 60 °C |
| Operating humidity | 0 to 60%, non-condensing |
| Warranty | 2 years |
| Mount | 2 Wall-mount holes |
| Input | K-Type Thermocouple |
| Output | Radio signal |
FTH1260-11-Usermanual-EN