Mushroom farming control
Controls temperature, humidity and CO₂ in mushroom growing rooms through every growth stage, and reports a deviation before the crop is damaged.

Why this monitoring is needed
Mushrooms are more sensitive to environment than any greenhouse crop, and worse, their optimum changes through the cycle: spawn run, pinning and cropping each want different temperature and CO₂. One fixed setting for the whole cycle guarantees a weak yield.
CO₂ is decisive and the source of most mistakes. High concentration produces long stems and small caps — exactly the mushroom a buyer rejects. Without measurement, no operator can guess a room's CO₂ level.
What gets measured
Air and compost temperature
Compost temperature differs from air temperature and governs the spawn run; a PT100 goes into the bed itself.
Room relative humidity
Low humidity cracks the caps; high humidity invites fungal disease.
CO₂ concentration
A 4–20 mA CO₂ transmitter drives the fresh-air command.
AHU and humidifier operation
Motor current proves fan and humidifier are actually working — in a mushroom room a few hours of stoppage is enough.
Room power and backup
A power cut in a mushroom room means losing the cycle; it has to be reported within the minute.
Recommended equipment
Every model below is from the Fidar Electronics range. The final combination is set after a site survey or an engineering consultation.

FCD6455-01
FIDAQUIRE FCD6455-01 Industrial Data Logger
Central logger holding the staged cycle programme with SMS alerts
View product ←
FBC0232-01
FBC0232-01 CANopen Input Card
CANopen card chaining sensors across several rooms
View product ←
FTA3070-01
Temperature and Humidity Sensor
Room air temperature and humidity sensor, several per room
View product ←
FTR0100-01
PT100 Temperature Sensor
PT100 sensor for compost bed temperature
View product ←
FAC0420-01
4–20 mA Current Sensor
4–20 mA input for the CO₂ transmitter
View product ←
FAC2000-23
3-Channel Networked AC Current Sensor
3-channel AC current sensor for AHU, humidifier and circulation fan
View product ←
FDV0220-01
AC Voltage Detector
AC voltage detector for room power
View product ←
FDR0508-01
FDR0508-01 8-Channel Relay Output Card
8-channel relay card for fresh air, heating, cooling and humidification
View product ←Alarm and automation rules
- 1
Temperature, humidity and CO₂ thresholds are defined per cycle stage and switch over automatically at the right time.
- 2
CO₂ above the stage threshold: fresh-air damper opened by relay with the deviation duration logged.
- 3
Humidity below threshold: humidifier on. Above threshold: ventilation increased.
- 4
AHU current lost: immediate SMS with no delay.
- 5
Room power loss: critical alarm over GSM, independent of site power and network.
What the operator gets
Mushroom grade improves with CO₂ under control, raising the first-grade share.
Losing a cycle to an overnight equipment failure is effectively eliminated.
Every cycle's conditions are recorded, making good and bad cycles comparable.
Frequently asked questions
Is one logger enough for several rooms?
Yes. Each CANopen card supports up to 64 sensors and the chassis has two slots, expandable to five. Thresholds are set per room, since rooms are usually at different cycle stages at the same time.
Will a sensor survive at 95 % humidity?
Fidar's temperature and humidity sensor reads up to 100 % RH, but its rated operating condition is non-condensing. In a mushroom room the sensor must sit in a vented protective housing away from direct water spray — build that into the installation design.
Related solutions
Want this solution on your own site?
Send us the site details and we will put together the equipment list and a technical proposal to match.