Wired CANopen

35 products in this group

Filter by capability

Clear all

Products

35 products

4–20 mA Current Sensor

FAC0420-01

4–20 mA Current Sensor

The 4–20 mA Current Sensor from Fidar Electronics reads the standard 4–20 mA output of any industrial transmitter and maps it back to engineering units. It connects to a FIDAQUIRE data logger over a daisy-chained CANopen bus.

View product
3-Channel 4–20 mA Current Sensor

FAC0420-02

3-Channel 4–20 mA Current Sensor

The 3-Channel 4–20 mA Current Sensor from Fidar Electronics reads the standard 4–20 mA output of any industrial transmitter and maps it back to engineering units. It connects to a FIDAQUIRE data logger over a daisy-chained CANopen bus.

View product
AC Current Sensor

FAC2000-01

AC Current Sensor

The AC Current Sensor from Fidar Electronics measures RMS alternating current from 0 to 5 A, and reaches much larger feeders through a current transformer. It connects to a FIDAQUIRE data logger over a daisy-chained CANopen bus.

View product
DC Current Sensor

FAC2000-02

DC Current Sensor

The DC Current Sensor from Fidar Electronics measures direct current in a circuit across a 0 to 5 A range. It connects to a FIDAQUIRE data logger over a daisy-chained CANopen bus.

View product
3-Channel AC Current Sensor

FAC2000-03

3-Channel AC Current Sensor

The 3-Channel AC Current Sensor from Fidar Electronics measures RMS alternating current from 0 to 5 A, and reaches much larger feeders through a current transformer. It connects to a FIDAQUIRE data logger over a daisy-chained CANopen bus.

View product
3-Channel DC Current Sensor

FAC2000-04

3-Channel DC Current Sensor

The 3-Channel DC Current Sensor from Fidar Electronics measures direct current in a circuit across a 0 to 5 A range. It connects to a FIDAQUIRE data logger over a daisy-chained CANopen bus.

View product
FAM4400-01 Analogue Input Card

FAM4400-01

FAM4400-01 Analogue Input Card

The Fidar Electronics FAM4400-01 analogue input card offers four voltage and four current channels at 24-bit resolution, logging in real time into a FIDAQUIRE data logger.

View product
0–10 V Sensor

FAV0010-01

0–10 V Sensor

The 0–10 V Sensor from Fidar Electronics reads the 0–10 V analogue signal of industrial and building equipment and turns it into a logged, alarmable value. It connects to a FIDAQUIRE data logger over a daisy-chained CANopen bus.

View product
3-Channel 0–10 V Sensor

FAV0010-02

3-Channel 0–10 V Sensor

The 3-Channel 0–10 V Sensor from Fidar Electronics reads the 0–10 V analogue signal of industrial and building equipment and turns it into a logged, alarmable value. It connects to a FIDAQUIRE data logger over a daisy-chained CANopen bus.

View product
AC Voltage Level Sensor

FAV0220-03

AC Voltage Level Sensor

The AC Voltage Level Sensor from Fidar Electronics measures mains RMS voltage from 50 to 250 V and records every sag and surge. It connects to a FIDAQUIRE data logger over a daisy-chained CANopen bus.

View product
DC Voltage Level Sensor

FAV0220-04

DC Voltage Level Sensor

The DC Voltage Level Sensor from Fidar Electronics reads DC voltage from 0 to 24 V and records how it sags over time. It connects to a FIDAQUIRE data logger over a daisy-chained CANopen bus.

View product
3-Channel AC Voltage Detector

FAV0220-05

3-Channel AC Voltage Detector

The 3-Channel AC Voltage Detector from Fidar Electronics reports whether an AC line up to 220 V is live and timestamps every loss and restore. It connects to a FIDAQUIRE data logger over a daisy-chained CANopen bus.

View product
3-Channel DC Voltage Detector

FAV0220-06

3-Channel DC Voltage Detector

The 3-Channel DC Voltage Detector from Fidar Electronics reports whether a DC circuit up to 60 V is energised and raises the alarm the moment it is not. It connects to a FIDAQUIRE data logger over a daisy-chained CANopen bus.

View product
FBC0232-01 CANopen Input Card

FBC0232-01

FBC0232-01 CANopen Input Card

The Fidar Electronics FBC0232-01 CANopen input card reads up to 64 CANopen sensors in real time into a FIDAQUIRE data logger, with automatic end-of-line termination detection.

View product
Dry Contact Detector

FDD0001-01

Dry Contact Detector

The Dry Contact Detector from Fidar Electronics reads the open or closed state of volt-free equipment contacts and turns every change into an alertable event. It connects to a FIDAQUIRE data logger over a daisy-chained CANopen bus.

View product
3-Channel Dry Contact Detector

FDD0001-02

3-Channel Dry Contact Detector

The 3-Channel Dry Contact Detector from Fidar Electronics reads the open or closed state of volt-free equipment contacts and turns every change into an alertable event. It connects to a FIDAQUIRE data logger over a daisy-chained CANopen bus.

View product
2-Channel Relay Module

FDR0102-01

2-Channel Relay Module

The 2-Channel Relay Module from Fidar Electronics provides two relay outputs, driven remotely or from a sensor threshold. It connects to a FIDAQUIRE data logger over a daisy-chained CANopen bus.

View product